• Phone: +91-9821604036
  • marketing@lablink.in

Gas Generator

OLYMPIA AN60-1 LCMS Nitrogen Generator provides nitrogen up to 30 Nl/min + Dry Air up to 55 Nl/min at 7.5 bar pressure Quiet: noise level reduced to a minimum thanks to special soundproof and anti-vibration devices
Scroll Oil Free Compressor Speed controlled electronically from the compressor head to save energy and reduce maintenance Monophase power supply 230 Vac 50/60 Hz
Monophase power supply 230 Vac 50/60 Hz Output Dew Point up to - 40°C
Two built-in air reservoirs of 15 liters each Compact and complete with all control devices
Integrated with MOD-BUS and MQTTS communication protocols, RJ45 cable -and WiFi, that allow remote controls from PC or smart phone, and monitoring of the generator’s functional parameters in real time through the Claind4You IoT platform. Remote Control: Remote connection to any device with the IoT Claind4You platform

MAX FLOW RATE CAPACITY

 Dry Air + Nitrogen =  70Nl/min

FLOW RATE Combinations Examples

Gas

Use

Capacity Nl/min

Pressure bar

AB SCIEX Conf.1

Nitrogen

Curtain & CAS Gas

18

3.8 ÷ 4.2

Dry Air

Source Exhaust

25

3.8 ÷ 7.3

Dry Air

Gas 1 – Gas 2

26

7.0 ÷ 7.3

AB SCIEX Conf.2

Nitrogen

Curtain & CAS Gas

18

3.8 ÷ 4.2

Nitrogen

Source Exhaust

25

3.8 ÷ 7.3

Dry Air

Gas 1 – Gas 2

26

7.0 ÷ 7.3

MP-AES Organic

Nitrogen

Plasma support Gas

25

4.5 ÷ 6

Dry Air

POP Gas

25

4.5 ÷ 6

Dry Air

EGCM

1.5

4.5 ÷ 6

Dry Air

Monochromator Air purge

10

4.5 ÷ 6

AIR COMPRESSOR TECHNOLOGY

Oil free SCROLL

OUTPUT PRESSURE

7.5 bar

ELECTRICAL SUPPLY

230 Vac ± 10% 60 Hz  2.5kW  Single Phase

PROTECTION INDEX

IP20

NOISE

Minimum: 54 dBA    Medium: 58 dBA

OPERATING TEMPERATURE

5°C - 40°C/40°F - 100°F

STORAGE TEMPERATURE

5°C - 50°C/40°F - 125°F

ENVIRONMENTAL HUMIDITY

max 90% without condensation

MAX ALTITUDE

Tested up to 2000 m from the sea level

DIMENSIONS

L x D x H cm 68 x 83 x 79.5        27.8” x 32.5” x 31.5”

WEIGHT

155 kg/330 lbs

THERMAL DISPERSION

2340 J/sec

PNEUMATIC CONNECTIONS

Air and nitrogen outlet G1/2” female

Condensate drain PVC pipe Øe 9 mm and collection tank

ELECTRICAL CONNECTION

5 mt power supply cable; Plug IEC309, 2-poles plus blue earth 32° IP44 according to standards IEC 60309-1 and IEC 60309-2

DATA CONNECTOR

Ethernet MQTTS, MOD- BUS data communication protocol; RJ45 cable - WiFi

For LCMS single or multiple installation, MP-AES and all analyzers looking for dry air and nitrogen


Subscribe to our News & Events