• Phone: +91-9821604036
  • marketing@lablink.in

Lab Water Purification System



Description

LABaQUa ultrapure water purification system provides you reliable and compact system which produces Ultra-pure water.
System always ensures high comfort at low operating cost.
LABaQUa lab water purification system is equipped with reverse osmosis (RO) system with additional resin to produce Type II water. This Type II water get stored in 50/100 ltr storage tank equipped with level sensor having high water level cut off. Type II water can be dispense directly from tap of storage tank.
Further Ultrapure water (Type I water) is produced with a combination of optimized cartridges with UV, Ion Exchange Resins & other polishers.
System comes with in-built printer (optional) for real time data printout.
System comes with predefined volume dispenser (optional).
Final Type I water comes through 0.2 μm filter disc.


System comes with touchscreen display & built in indication of following parameters.

  • Temperature & Conductivity of feed water & Ultra-Pure (Type I) Water
  • Flow rate indicator for R.O. water (Type II) & Ultra- Pure (Type I) Water to ensure proper output of system.
  • Real time data of total water dispense volume for R.O. water (Type II) & Ultra-Pure Water (Type I) to ensure life of consumables.
  • UV lamp working hours to ensure life of UV lamp.
  • Type II & Type I water pumps working hours.
  • Type I & feed water conductivity meter calibration due indication.
  • Visual Alarm indication in case of high conductivity of Type I & feed water.

The input water required is DM water/RO water or Municipal Water. Easy to install, repair, plug and play. Suitable for Indian Conditions. Very low consumable cost.
System have calibrated conductivity meters. Design of the instrument is electrically and electronically safe, as the Electrical & Electronic circuits never come in touch with water which enhances safety.

Parameters Specification
Type I Water
Dispensing Rate of Ultra-Pure System: 2 LPM
Resistivity of Ultra-Pure Water: 18.2M Ω cm at 25°C
Conducitivity μS/cm: 0.055 μS/cm at 25°C
TOC: <50 ppb
Chloride max.: <1ppb
Total Silica (ppb): <3ppb
Endotoxin: <0.25 EU/ml
Sodium max.: <1ppb
Type II Water
Production Rate: 50 LPH
Conductivity μS/cm: <1 μS/cm
Chloride max.: <5 ppb
Total Silica: <3 ppb
Storage Tank: 50/100 ltr. tank with level sensor & tap
Electrical Power Supply: 230 VAC
NOTE: These values are typical and may improve further depending on the nature and concentration of contaminants in the feed water.
Chromatography: HPLC, UPLC, LC-MS and GC
Elemental Analysis: AA, GFAA, ICP-MS, ICP-OES and ILc
Cell Culture: Lab Washers
Molecular Biology and Bio-chemistry PCR, DNA, Autoclaves, Analyzers, Sequencing, DNA Micro array, Electrophoresis and Blotting, Clinical Laboratories CLSI-CLRW Guidelines

Subscribe to our News & Events